Shower Waterproofing Membrane

Shower Waterproofing Membrane

Shower Waterproofing Membrane is a waterborne flexible SBR waterproof membrane designed for use under tiled finishes that is capable of accommodating expected structural movement. It complies with the performance requirements of Building Code of Australia 2007 Clause FP1.4 and FP1.7 (Volume 1 – Class 2 to Class 9 buildings) and P2.2.2 and P2.4.1 (Volume 2 – Class 1 and Class 10 building Housing Provisions).  May be used under cement based tile adhesives that meet the requirements of Australian Standard 2358. VOC Content of Shower Waterproofing Membrane is below the maximum VOC Content for Architectural and Interior Sealants as required by Green Star Office Design V2, V3, Office Interiors V1.1, and APAS D181.

View more from: Waterproofing Products

  • Features & Benefits
  • Areas of Use

Features & Benefits

  • Permanently flexible - accommodates cracking in substrate
  • Dries to a keyed finish to promote adhesion with tile adhesives
  • Single pack
  • Quick drying
  • Safe and easy to use
  • No priming required
  • Designed for use with a bond-breaker – Reinforcing Fabric with Bond Breaker.
  • Impervious to moisture
  • Excellent adhesion to a wide variety of substrates
  • Class III Membrane to AS 4858
  • Complies with Building Code of Australia FP1.4 and                               
  • FP1.7 and P2.2.2 and P.2.4.1                                        
  • Complies with AS 3740

Areas of Use

  • Shower recesses
  • Bathroom floor areas
  • Laundries
  • Kitchens
  • Balconies
  • Patios
  • Concrete, cement render, plaster
  • Hardie/CSR sheet flooring
  • Brick
  • Light weight aggregate block
  • Plasterboard, MDF
  • Plywood sheet flooring
  • Steel (suitably primed)
  • Wet area wall lining board

How to waterproof a shower

Instructions

  • YOU WILL NEED

    YOU WILL NEED

    A 4 litre kit will treat a 2 wall shower recess.
    A 6 litre kit will treat a 3 wall shower recess.

  • EQUIPMENT

    EQUIPMENT

    Reinforcing Fabric with Bond breaker and a brush to apply the membrane

  • NUMBER OF COATS

    NUMBER OF COATS

    2 coats are required and should be applied at 90° to each other.

  • DRYING TIME

    DRYING TIME

    Allow 2 hours drying time between coats. Suitable to be tiled over after 48 hours

  • CLEAN UP

    CLEAN UP

    Shower Waterproofing Membrane is easily cleaned up with water before it dries

  • TIPS

    TIPS

    Pre cut reinforcing fabric prior to installing in corners and around drainage outlets. Do not try to build up the coating thickness in one coat